Ultra Fire Lintels

A range of Ultra Fire Lintels with an enhanced fire resistance. Due to the special coating applied, all sections can achieve 240 minute load bearing capability when subject to fire conditions.

Finish

These lintels have a slightly different texture to concrete but are smooth . They can also be left natural but we would advise the use of a waterproof sealant to reduce surface dusting.

Order/Specification code

As per the product range (e.g. Ultra-Fire 100-6,Ultra-Fire 100-9, Ultra-Fire 140-6, Ultra-Fire 140-9, Ultra-Fire 215-9.)

Ultra Fire Range 100-6 140-6 100-9 140-9 215-9
Fire Resistance Available (mins) 240 240 240 240 240
Suitable for Foundation Use no no no no no
Maximum Length Available 2700mm 2400mm 3600mm 3900mm 3900mm
Manufactured in 50mm increments from 300mm
Unfactored Loads in kN/m
Length Clear Span 100×140 140×140 100×215 140×215 215×215
900mm 700mm 30.09 18.35 50.27 74.70 117.36
1100mm 900mm 22.21 11.23 40.11 59.61 88.69
1200mm 1000mm 18.24 9.10 36.42 54.13 73.10
1500mm 1200mm 12.90 6.27 29.03 40.25 51.21
1800mm 1500mm 8.36 3.91 19.32 26.42 33.53
2100mm 1800mm 5.81 2.60 13.42 18.57 23.50
2400mm 2100mm 4.23 1.80 9.90 13.69 17.27
2700mm 2400mm 3.19 n/a 7.57 10.45 13.14
3000mm 2700mm n/a n/a 5.94 8.19 10.26
3300mm 3000mm n/a n/a 4.76 6.56 8.17
3600mm 3200mm n/a n/a 4.71 5.71 7.08
Lintel Weight kg/m 35 47 51 72 111